Lead-acid batteries can be charged manually with a commercial power supply with adjustable voltage and current limiting. Calculate the charge voltage according to the number of cells and desired voltage limit. Charging a 12 volt Dell Inspiron 1521 Battery (6 cells) to limit voltage 2.40V cell, for example, would require a voltage setting of 14.40V.
The charge current for small lead-acid batteries should be set between 10% and 30% of nominal capacity (30% of a 2Ah Inspiron 6000 Battery would be 600mA). larger batteries, such as those used in the automotive sector, are generally subject to lower the current ratings. Cells constructed of a material not lead antimonial grid allow higher charge currents but have a lower capacity. The cyclone cylinder is sealed and can withstand a pressure of up to 3.5 bar (50 psi). A cell pressure helps gas recombination.

Observe the Dell D800 Battery temperature, voltage and current during charging. Load only at room temperature in a well ventilated area. Once the XPS m1210 battery is fully charged and the current is decreased to 3% of rated current, the charge is completed. A good car VGP-BPS2C battery will drop to about 40 mA with a full charge, a defective battery can not fall below 100mA.
After full charge, remove the Inspiron E1705 Battery from the charger. If you need to float charge for operational readiness, reduce the charging voltage of about 13.50V (2.25V/cell). Most chargers perform this function automatically. The float charge can be applied indefinitely.
While in the houseboat-charge, an external load can be connected to a lead-acid Dell 500m Battery. In this case, the XPS M1210 acts as a buffer. Micro-cell towers on sites work this way. During off-peak periods, the batteries are charged. The timing of peak traffic, when the load exceeds the net supply provided by the rectifier (charger) and the Asus A2000 battery provides extra energy. A car battery works similarly.
When you configure a buffer Inspiron Mini 10 battery, make sure that the Dell xps m1730 battery can fully charge between loads. The net charge must be greater than it is drawn from the Latitude X300 Battery. Some chargers switch to fast charge after a deep discharge, others simply use the floating charge to recharge. Wait up to 48 hours to fully charge a fee float. deep discharges should be avoided if possible. Make sure the float charging voltage is set correctly.